User's Manual

Table Of Contents
Installation RF Path Elements CMA-331-AEN Page 109
Draft
Figure 5-55. RIM, OIM and HCM/ACM LEDs
5.2 RF Remote-End Installation
The remote end site (RF coverage) installation consists of installing the ICU and RAU module(s).
5.2.1 ICU Installation
Note the following:
The ICU is a passive unit installed at the floor level and provides the power and fiber interfaces to the RAU units (and to the
GEU for the digital path).
Connections between the ICU and the RAU units are performed via Corning composite cables (ordered separately)
consisting of:
2 DC wires
3 LC APC pairs
Chassis and modules are supplied separately and must be inserted by the user
All ICU modules (i.e. PS and Edge) are hot-swappable
Each ICU chassis hosts up to four Power Supply modules and up to two Edge modules