User's Manual

Table Of Contents
Installation RF Path Elements CMA-331-AEN Page 108
Draft
5.1.4.11 Verify Normal operation
1. Verify that the Power Status LED on each PSM shows green. See Figure 5-16 (PSM-AC) and Figure 5-19 (PSM-DC).
2. Referring to Table 5-8 and Figure 5-55 - verify that the RIM (if RF source is operational), OIM and HCM/ACM LEDs indicate
normal operation.
Module LED Description
RIM Protect N/A
DL High Off - DL RF input level in threshold range
Steady Red DL RF input level is 3 dB above max expected power
DL Low Off - DL RF input level in threshold range
Steady Red - DL RF input level is 15 dB below max expected power
RUN Blinking Green - RIM module SW has initialized and is up and running
Off Power off
PWR Steady green - Input power is within required range
OIM Link 1/2/3 Steady Green - Optical link power to/from the connected remote is normal
Blinking Green - Optical power from remote is lower than required
Run Blinking Green - OIM module SW has initialized and is up and running
Off Power off
PWR Steady Green - Power input detected in OIM
HCM/ACM PWR Steady Green - Power input detected by HCM/ACM
RUN Blinking Green - HCM module SW up and running
SYS Steady Green - Overall status of the managed system is ok
FAN Steady Green - Normal operation status for all fans
Table 5-8. RIM/OIM and HCM/ACM LED Descriptions