Installation CMA-438-AEN Page 35
Draft
4.7 MRU Installation with Outdoor Enclosure
This section provides instructions on how to install the MRU in a Purcell Systems cabinet (Flexsure
®
12-2420) and perform
external alarm connections between the unit and the enclosure.
Note the following:
The MRU, outdoor enclosure and required dry contact alarms cable are each ordered separately
Additional relevant documentation - Purcell Flexsure 12-2420 installation manual provided with the cabinet
Only trained and qualified personnel should be allowed to install, replace, or service this equipment
The MRU connections are performed after the chassis is installed in cabinet
4.7.1 Items Required for Outdoor Installation
Refer to Table 4-3 for the items required for installing the MRU in the outdoor enclosure.
Kit Item Quantity
FLX12-2420 Enclosure
Purcell Systems Flexsure
®
12RU Outdoor GR-487
Enclosure for single MRU installations
1
MRU Mid-Power remote unit 1
External Alarms Cable
(AK-MRU-DCA-CBL)
DB9 male open wire cable for external alarm connections 1
Table 4-3. Items Required for Outdoor Installation
Additional required items (not provided):
Standard electrician tools (including ratchet wrench with extension bar and 8 mm socket) for tightening self-drilling
screws securing MRU chassis to cabinet rails)
Assorted cable ties
90
right angle
4.3-10 type male connector coax cables one for antenna connection and one for external 2.5 GHz RF
source connection (if relevant)
Recommended - flexible cable conduits for routing connections cables through cabinet knockouts; refer to Figure 4-13
for relevant knockouts; Following are recommended Heyco part numbers for flexible conduits:
Manufacturer PN Description
8406 HFC 1 BLACKw/8467 Nut, conduit fitting 1 in thread
8453 HF2 1 Tubing 100’ Coil Black
8456 HFC 2 Tubing 50’ Coil Black
8642 HFC 2 Black; conduit fitting 2 in thread
Table 4-4. Recommended Conduits
Sealing material for knockouts if not using conduits