User's Manual

Table Of Contents
Appendix A: Specifications CMA-XXX-AEN Page 44
Draft
Physical Specifications
MRU hosting capabilities
Five service specific Power Amplifier Modules (PAM)
One Optical Module (OPTM)
One Fan Module (FAM)
One AC or DC (model dependant) Power Entry Module
Interfaces
One 4.3-10 type duplexed RF antenna port
One LC APC port for fiber optic connection
One QMA coupling ‘Test Port’ (used for UL and DL measurements during
system operation)
One 4.3-10 type RF port for 2.5 GHz external RF source
One RJ-45 MGMT (local) connection
One two-hole, standard barrel grounding lug; for use with stranded copper
wire conductors; 10-14 AWG; holes - 1/4 inch
DC IN Connectors (model dependant):
One DC In two pin ‘Class 1’ terminal block
Two DC Ineight pin Class 2terminal block connectors: one pair for
each PAM ( total of five pairs) and one pair for the FAM+OPTM; one RSV
pair
One QMA input connector for EXP UL
One QMA output connector for EXP DL
One DB-9 female external alarm connector for external dry contact alarm
connections
Power
Power Consumption: DC Version: 330 W (maximum) AC Version: 360W (maximum)
AC: Power Input: 100-240 VAC/50-60 Hz;
Max. AC
Current
Consumption
5A
DC: Power Input
DC class 1- 48VDC (40-60VDC) 9 A max
DC class 2- 24VDC/48VDC (20VDC 60VD)1.75 A maximum per pair
Power amplifier consumption per pair: 50 W
Management
Managed via the Headend Control Module (HCM )
Physical
Characteristics
(Enclosure and
Modules)
Mounting: 19-in rack; (6U rack height)
Wall mount (separately ordered accessory kit)
Dimensions (H x W x D):
10.5 x 17.5 x 15.75 in (266.7 x 445 x 400 mm)
Weight (fully populated
with five bands):
70.55 lbs (32 kg)