Introduction CMA-XXX-AEN Page 10
Draft
1.2 General System Specifications and Requirements
1.2.1 Environmental and Regulatory Specifications
Operating
Storage
Temperature -40° C to +65° C (-40°F to 149°F)
-30° to 85°C (-22° to 185°F)
Table 1-1. Temperature and Humidity Specifications
1.2.2 Safety and Regulatory Approvals
Regulation/Standard
Category
Approval
Laser Safety
FDA/CE 21 CFR 1040.10 and 1040.11 except for deviations pursuant to laser notice no.
50 and IEC 60825-1
EMC FCC 47 CFR Part 15, 22, 24, 27
Safety UL 60950
IEC 60825-1:2007
IEC 60825-2:2010
CAN/CSA-C22.2 No.60950-1-03
NEBS GR-63, GR-1089
Table 1-2. Safety and Regulatory Approvals
1.2.3 Power Specifications
Power Spec
Description
Power consumption (max.) 360 W (for fully loaded chassis)
AC: Power input 100-240 VAC/50-60 Hz
Max. current
consumption
5A
DC: Power input
DC class 1 (Local feed): 48 VDC (40-60 VDC) 9A max
DC class 2 (Remote feed): 24VDC/48VDC (20VDC – 60VD)1.75A max per pair
Power consumption per pair: 50 W