MOTOR CHECK
The resistance readings on the winding will be between 5 to 25 ohms. A meter capable of these low readings must
be used. The start relay cover must be removed. (See Figure 7).
If no continuity on start or run winding test, replace gearmotor. If continuity on grounded motor test, replace
g
earmotor.