67
312028000
Trouble RemedyProbable Cause
CARBONATOR WATER PUMP
WILL NOT SHUT OFF.
A. Binding, damaged, or dirty
carbonated water tank balance
mechanism.
A. Clean, repair, or replace balance
mechanism.
ERRATIC CARBONATOR
WATER PUMP CYCLING.
A. Insufficient water supply
pressure. ‘‘H
2
O OUT’’ fault
message goes on and off
intermittently and water pump
cycles on and off during
carbonator tank fill cycle.
A. Increase water inlet supply line
pressure. Water inlet supply line
must have large enough I.D.
B. Water filter restricted. B. Replace water filter.
TROUBLESHOOTING DISPENSED PRODUCT
BRIX (WATER-TO-SYRUP)
‘‘RATIO’’ TOO LOW.
A. Quick disconnect not secure
on soft drink tank.
A. Secure tank quick disconnect.
B. Syrup flow regulator set too
low.
B. Adjust BRIX of dispensed product
as instructed.
C. Water flow regulator set too
high.
C. Water flow regulator must be set
at 1.3 ± 0.05 oz/sec.
D. Syrup flow regulators stuck. D. Clean syrup flow regulators.
E. Restriction in syrup line. E. Sanitize Unit as instructed.
F. Syrup Baume not in proper
range.
F. Change syrup supply as
instructed.
BRIX (WATER-TO-SYRUP)
‘‘RATIO’’ TOO HIGH.
A. Syrup flow regulators set too
high.
A. Adjust BRIX of dispensed product
as instructed.
B. Water flow regulator set too
low.
B. Water flow regulator must be set
for 1.3 ± 0.05 oz/sec.
C. Water flow regulator stuck. C. Clean regulator.
D. Syrup Baume not in proper
range.
D. Change syrup supply as
instructed.
E. Restricted water filter. E. Replace water filter.
IMPROPER PRODUCT
DISPENSED.
A. Secondary CO
2
regulators not
properly adjusted.
A. Adjust secondary CO
2
regulators
as instructed.
B. Dirty CO
2
supply. CO
2
must
be clean and free of water, oil,
and dirt. Water will not absorb
dirty CO
2
gas in same way as
clean gas. This can also cause
off-taste problems.
B. Replace CO
2
supply as
instructed.
PRODUCT WILL NOT
DISPENSE OUT OF
DISPENSING VALVE, IN ONLY
SMALL AMOUNTS, OR ONLY
LIQUID.
A. Dispensing valve has ice
particles in it.
A. Open and close dispensing valve
repeatedly. Defrost freeze cylinder
as instructed. If necessary, check
and adjust BRIX as instructed.
Adjust viscosity of dispensed
product as instructed.
B. Cylinder freeze-up. B. Refer to CYLINDER FREEZE-UP.
FREEZE CYLINDER DOES
NOT REFILL AT ALL TIMES
WHEN DISPENSING.
A. ‘‘AUTO BLEND 1’’ or ‘‘AUTO
BLEND 2’’ switch not pressed.
A. Press ‘‘AUTO BLEND 1’’ or
‘‘AUTO BLEND 2’’ switch.
B. Carbonator water pump not
operating.
B. Check carbonator and restore to
operation.