- IMI Cornelius Beverage Dispenser User Manual
25 312028000
ITEMS AFFECTED BY ERROR
MESSAGE
DISPLAYED ERROR
BEATER
MOTOR 1
BEATER
MOTOR 2
REFRIG 1 REFRIG 2
Motor 1 Low Current, < 109,
Sensed on Motor One
OFF OFF
Motor 2 Low Current, < 109,
Sensed on Motor Two
OFF OFF
Motor 1 High Current > 255,
Sensed on Motor One
OFF OFF
Motor 2 High Current > 255,
Sensed on Motor Two
OFF OFF
REFRIG **Maximum Run Time on Compressor OFF OFF OFF OFF
SYRUP 1 Syrup Out Side One OFF
SYRUP 2 Syrup Out Side Two OFF
CO
2
OUT CO
2
Out OFF OFF
H
2
O H
2
O Out *OFF *OFF
SENSOR 1 Temp Sensor Inlet One OFF OFF OFF OFF
SENSOR 2 Temp Sensor Inlet Two OFF OFF OFF OFF
SENSOR 3 Temp Sensor Outlet OFF OFF OFF OFF
* The refrigeration system and carbonator shall continue to operate for 1.5 minutes after a water pressure loss
has been detected. If water pressure loss continues beyond 1.5 minutes, the refrigeration system and carbonator
will stop.
** 25 minutes on Standard System, 30 minutes on Remote System.
TABLE 9 DISPLAYED ERROR CONDITIONS
3. Press “CANCEL DEFROST” (ADVANCE) switch. The motor manufacturer’s name will start blinking.
4. Press the “CANCEL DEFROST” (ADVANCE) switch again, which will change to another blinking manufac-
turer’s name.
5. Keep pressing and releasing the “CANCEL DEFROST” (ADVANCE) switch until the applicable blinking
manufacturer’s name appears on the message display. This indicates manufacturer’s name of the No. 1
freeze cylinder beater motor (new Unit installation) or the new installed replacement motor.
6. After the applicable beater motor manufacturer’s name has been selected, press “DEFROST” (SELECT)
switch which will match the beater motor to the Unit electronics. The motor manufacturer’s name will no
longer be blinking.
7. Press “DEFROST” (SELECT) switch to return to “MOT_MFG1”.
8. Press “CANCEL DEFROST” (ADVANCE) switch to go from “MOT_MFG1” to “MOT_MFG2” (represents No.
2 freeze cylinder beater motor) which will appear on the message display.
9. Repeat steps 2 through 6 to program in the correct beater motor manufacturer’s name for No. 2 freeze
cylinder.
PROGRAMMING PROPER REFRIGERANT TYPE INTO UNIT ELECTRONICS
The Dispenser electronics must be programmed for the proper refrigeration pulse rate according to the type of
refrigerant gas that has been installed in the refrigeration system. Note Dispenser serial plate for the type of re-
frigerant gas that has been installed, then proceed as follows to program the Dispenser.