- IMI Cornelius Beverage Dispenser User Manual

19 312028000
DISPLAYED MODEL HZ MOTOR DESCRIPTION
KLBER
60 Klauber 60 Over/under gear box with a GE wide-range voltage motor.
FASV3+60 Fasco/VW 60 Over/under gear box with a Fasco wide-range voltage motor.
FASCWR 60 Fasco/VW 60 Standard gear box using a Fasco wide-range voltage motor.
VW/GE 60 Fasco/VW 60 Standard gear box with a GE 219/242 volt motor.
EMRSN 60 Emerson 60 Over/under gear box with an Emerson wide-range motor.
BODINE 60 Bodine 60 Special wide-range motor.
KLBER
50 Klauber 50 Over/under gear box with a GE wide-range voltage motor.
FASV3+50 Fasco/VW 50 Over/under gear box with a Fasco wide-range voltage motor.
FASCWR 50 Fasco/VW 50 Standard gear box using a Fasco wide-range voltage motor.
VW/GE 50 Fasco/VW 50 Standard gear box with a GE 219/242 volt motor.
EMRSN 50 Emerson 50 Over/under gear box with an Emerson wide-range motor.
TABLE 6. MOTOR SELECT
DIP SWITCH
NO. 1
DIP SWITCH
NO. 2 *MESSAGE
OFF OFF ENJOY A FROZEN BEVERAGE
OFF ON NOT USED - BLANK
ON OFF HAVE A NICE DAY
ON ON DISFRUTE UNA BEBIDA CONGELADA CARBONATADA
*For special messages, contact your local sales representative.
TABLE 7. POINT OF SALE DISPLAY MESSAGES
PROGRAMMING ‘‘WAKE UP’’ (WAKE UP TIME) INTO UNIT
‘‘WAKE UP’’ (WAKE UP TIME) may be programmed into Unit to occur any time of the day to wake Unit up (return
to normal operation) after ‘‘sleep time’’ has occurred. Program ‘‘WAKE UP’’ into Unit as follows:
1. Refer to PROGRAMMING MAIN MENU SELECTIONS ONTO MESSAGE DISPLAY and bring up ‘‘WAKE
UP’’ on message display. Press ‘‘DEFROST’’ (SELECT) switch to lock in on selection.
2. Press ‘‘CANCEL DEFROST’’ (ADVANCE) switch to bring up flashing hour number on display.
3. Press ‘‘CANCEL DEFROST’’ (ADVANCE) switch to advance hours on display to desired hour. Press ‘‘DE-
FROST’’ (SELECT) switch to lock in hour on display.
4. After hour (time of day) has been locked in on message display, minute numbers will be flashing on display.
Press ‘‘CANCEL DEFROST’’ (ADVANCE) switch to advance minute numbers to desired minutes (time of
day). Press ‘‘DEFROST’’ (SELECT) switch to lock in minutes (time of day) on display.
5. Press ‘‘ERROR RESET’’ switch two times to exit from MENU SELECTIONS.
PROGRAMMING POINT OF SALE MESSAGE DISPLAY
(see Figure 4 and 7)
NOTE: Point of sale display messages may be turned off by placing No. 1 DIP SWITCH on master circuit
board in OFF position and No. 2 DIP SWITCH in ON position (see Figure 4 and 5 and 7).