- IMI Cornelius Beverage Dispenser User Manual

10
312028000
INSTALLING PRIMARY CO
2
REGULATOR ASSEMBLY ON CO
2
CYLINDER
(see Figure 2)
WARNING: To avoid personal injury and/or property damage, always secure CO
2
cylinder in
upright position with a safety chain to prevent it from falling over. Should the valve become
accidentally damaged or broken off, CO
2
cylinder can cause serious
personal injury.
WARNING: CO
2
displaces oxygen. Strict attention must be observed in the prevention of
CO
2
(carbon dioxide) gas leaks in the entire CO
2
and soft drink system. If a CO
2
gas leak is
suspected, particularly in a small area, immediately ventilate the contaminated area before
attempting to repair the leak. Personnel exposed to high concentration of CO
2
gas will experience
tremors which are followed rapidly by loss of consciousness and suffocation.
1. Unscrew protector cap (with chain attached) from CO
2
cylinder valve. Open CO
2
cylinder valve slightly
counterclockwise to blow any dirt or dust from outlet fitting before installing primary CO
2
regulator, then
close valve.
2. Remove shipping plug from primary CO
2
regulator assembly coupling nut and make sure gasket is in place
inside nut. Install regulator assembly on CO
2
cylinder so gages can be easily read, then tighten coupling
nut. DO NOT OPEN CO
2
CYLINDER VALVE AT THIS TIME.
CONNECTING SOFT DRINK TANKS CO
2
LINES TO PRIMARY CO
2
REGULATOR
ASSEMBLY
(see Figure 2)
1. Connect soft drink tanks CO
2
lines to primary CO
2
regulator manifold assembly as shown in Figure 2.
2. Install gas quick disconnects on ends of soft drink tanks CO
2
lines. DO NOT CONNECT CO
2
LINES TO
TANKS AT THIS TIME.
PREPARING UNIT SYRUP INLET LINES FOR CONNECTION TO SOFT DRINK TANKS
(see Figure 2)
1. Route Unit syrup inlet lines labeled No. 1 and No. 2 to soft drink tanks location.
2. Install liquid quick disconnects on ends of Unit syrup inlet lines. DO NOT CONNECT SYRUP LINES TO
SOFT DRINK TANKS AT THIS TIME.
CONNECTING CO
2
SOURCE LINE TO UNIT CO
2
INLET LINE
(see Figure 2)
1. Connect and route a CO
2
source line from the primary CO
2
regulator up to the Unit.