Service manual

9
of the ice bank control. Never use an ice pick
or other instrument to remove ice from the
evaporator. Such practice can result in a
punctured refrigerant circuit or damage to the
water bath tank.
d. Once the ice bank is sufficiently melted, lift
the entire refrigeration deck up and away
from the water bath by lifting the deck using
it’s service handle strap.
e. Prepare 1 gallon (3.9 L) of cleaning and
sanitizing solution (see “Sanitizing the
Concentrate Lines & Valves”). Pour the
cleaning and sanitizing solution into the
water bath and clean the sides and bottom of
the tank, the product coils, and associated
brackets with a fiber brush.
f. Utilizing the cleaning and sanitizing solution
in the water bath, the fiber brush, and a
clean cloth soaked with sanitizing solution,
clean the refrigeration deck’s evaporator
coils, agitator motor shaft and blade, and the
ice bank sensing bulb.
g. Drain the cleaning and sanitizing solution
from the water bath and rinse/flush all the
components with clean water.
h. Re-install the refrigeration deck into the
water bath and secure with two screws.
i. Connect the refrigeration deck’s power strip
to the dispenser’s power cord. Connect the
red, white and blue 12 pin plugs to the
electrical box. Connect the key switch to the
transformer.
j. Fill the water bath with cool potable water
until water begins to flow from the overflow
tube.
k. Plug the merchandisers power cord into
power strip located on the refrigeration deck
and re-install the top bonnet. Secure the
bonnet assembly with two screws.
l. Install the splash panel and cup rest and plug
the dispenser’s power cord into the electrical
outlet.