Technical information
Non-Carbonated Impulse Installation & Operations Manual
Publication Number: 859000159INS - 3 - © 2003-2012, IMI Cornelius Inc.
INSTALLATION
!
WARNING:
It is the responsibility of the installer to ensure that the water supply to the dispensing equipment is provided with
protection back flow by an air gap as defined in ANSI A 112.1.2-1979; or an approved vacuum breaker or other such
method as proved effective by test and must comply with all federal, state and local codes.
Failure to comply could result in serious injury, death or damage to the equipment.
Water pipe connections and fixtures directly connected to a potable water supply shall be sized, installed and
maintained according to Federal, State and Local laws.
INSTALLATION REQUIREMENTS
Requirements Summary
18-Inches above 6-Inches on Sides and Rear
ELECTRICAL REQUIREMENTS
Before connecting electrical power to the unit refer to nameplate to verify power requirements
!
DANGER:
To avoid possible serious injury or death the ELCB (earth leakage circuit breaker) must be installed in electrical cir-
cuit of all 50 Hz units.
!
WARNING:
To avoid possible electrical shock the unit must be electrically grounded using the green grounding screw provided
inside the electrical contractor box.
CAUTION:
!
The wiring must be properly grounded and connected through a 10-amp disconnect switch (slow–blow fuse or
equivalent HVAC/R circuit breaker). ALL WIRING MUST CONFORM TO NATIONAL AND LOCAL CODES. MAKE
SURE UNIT IS PROPERLY GROUNDED
Weight
Front or rear counter must be level and able to support 400 lbs
Environment
Indoor Installation only
Temperature
40° To 110° F Ambient Temperature
Clearance
CO2:
75 Psi (5.25 Bar) At Unit With Internal Carbonator
Concentrate:
60 Psi
Water
50 Psi Maximum
Electrical:
See Nameplate On Unit For Electrical Requirements