Installation manual

1
630460001
GENERAL DESCRIPTION
UNIT DESCRIPTION
The Three-Flavor Tower is compact and may be island-mounted or installed on a front or rear counter. The
Three-Flavor Tower is designed to dispense three, portion controlled, noncarbonated drinks. One concentrate
flavor is chilled by a heat exchanger. Cooling for the heat exchanger is provided by the existing soft drink sys-
tem.
DESIGN DATA
Table 1. Design Data
Overall Dimensions:
Width 10.75 in.
Height 26.25 in.
Depth 9.12 in.
Ambient Operating Temperature:
40 degrees F (4.4 degrees C) to
90 degrees F (32 degrees C)
Electrical Requirements:
115VAC, 60HZ
Inlet Water Requirements:
Minimum Flow Pressure 40 psig
Maximum Static Pressure 55 psig
RECEIVING
Each Unit is completely tested under operating conditions and thoroughly inspected before shipment. At time of
shipment, the carrier accepts the Unit and any claim for damage in transit must be made with the carrier. Upon
receiving Unit from the delivering carrier, carefully inspect the carton for visible indication of damage. Any dam-
age or irregularities should be noted at this time (not later than 15 days from date of delivery) and immediately
reported to the delivering carrier. Request a written inspection from the carrier’s claims inspector to
substantiateclaim. File claim with the delivering carrier not with Cornelius Inc.