Technical information
Ice Frost Training Manual
© 2005, IMI Cornelius Inc. - 35 - Publication Number: TP01080
Does
unit have enough
clearance
Is
filter dirty or
restricted
Reposition unit
Clean filter or
condenser
Filter dirty
Unit not running
Is power
switch ON
Are
fuses OK
Is
high pressure
cutout tripped
Turn unit ON Replace fuses
Check fan and
condenser
Bowl not refilling
Are
syrup, H2O, and
CO2 satisfied
Is
fill switch
ON
Are
probes clear
of foam
Are
sold out lights
ON
CO2
Syrup
Test sold out
switch and replace
if defective
Test sold out
switch and replace
if defective
Unplug fill
probes. Does
bowl fill
Replace board
Replace probes
Yes Yes Yes
Yes
Yes
Yes
Yes
No
Yes
No
Correct Turn ON
Empty, flush, and
refill
No
No No
Yes Yes Yes
No No
No
Yes Yes