SPECIAL MAINTENANCE
ATTENTION: To guarantee peak cooling
system performance, the routine cleaning of
the condenser filter is essential.
As explained earlier, an audible signal accompanied by
the word FILT appearing on the control panel display,
will warn the operator when the filter is clogged and so
must be cleaned before the machine comes to an
automatic stop.
• Disconnect the machine from the power supply;
• Unscrew the nut (C in FIGURE 30).
• Remove the cover (B in FIGURE 30).
• Disconnect the plug (D in FIGURE 31).
• Loosen and rotate the bracket.
• Lift and remove the back (E in FIGURE 31).
• Clean the filter behind the net, then clean the
condenser with a brush, if necessary.
WARRNING: You are reminded that all the opera-
tions described above must be carried out with
the machine switched off and the power cable dis-
connected.
FIGURE 30
FIGURE 31
• Clean the CO
2
manifold while you have access to
the back of the unit.
A. Open the John Guest valve, shown in FIGURE
32, and allow the manifold CO
2
pressure to blow
any liquid that might be in the manifold out of
the tube.
FIGURE 32