Technical information

Ice Frost Training Manual
Publication Number: TP01080 - 20 - © 2005, IMI Cornelius Inc.
12. Unscrew the fastening knob (A) clockwise
as the direction indicated by the arrow
(threading to the left) and extract the spiral
scraper (C) and the seals (B) and (D).
Clean the individual parts thoroughly
(FIGURE 27).
FIGURE 27
13. Clean the drip tray (A) and the evaporator
(B) (FIGURE 28).
14. Replace the mixing unit as follows:
• Dampen the sealing strip (FIGURE 27,
D) and insert it into its seating.
• Apply a generous amount of food grade
lubricant (supplied with the machine) to
the suction cup seal (FIGURE 27, B) (on
the part that comes into contact with the
evaporator FIGURE 28, B) and insert it
in its spiral seating.
Replace the spiral scraper (FIGURE 27,
C).
• Fasten all the components in place by
screwing the knob (FIGURE 27, A)
counter-clockwise.
FIGURE 28
15. Replace the bowl by pushing it into its seating.
16. Fasten the bowl in place by tightening the knobs (FIGURE 23) and the locking bar (FIGURE 21).
17. Replace the tap, remembering to smear both is seating in the bowl and the seals with food grade
lubricant
18. Remove the drip tray (L1) by rotating it
slightly and pulling it outwards (FIGURE
29).
Wash all the parts carefully and
reassemble it by following the prior
operations, remembering to re-insert the
condensation discharge pipe (M1) in its
seating.
FIGURE 29
A
B
C
D
A
B