Technical information
Ice Frost Training Manual
Publication Number: TP01080 - 20 - © 2005, IMI Cornelius Inc.
12. Unscrew the fastening knob (A) clockwise 
as the direction indicated by the arrow 
(threading to the left) and extract the spiral 
scraper (C) and the seals (B) and (D). 
Clean the individual parts thoroughly 
(FIGURE 27).
FIGURE 27
13. Clean the drip tray (A) and the evaporator 
(B) (FIGURE 28).
14. Replace the mixing unit as follows:
• Dampen the sealing strip (FIGURE 27, 
D) and insert it into its seating.
• Apply a generous amount of food grade 
lubricant (supplied with the machine) to 
the suction cup seal (FIGURE 27, B) (on 
the part that comes into contact with the 
evaporator FIGURE 28, B) and insert it 
in its spiral seating.
• Replace the spiral scraper (FIGURE 27, 
C).
• Fasten all the components in place by 
screwing the knob (FIGURE 27, A) 
counter-clockwise.
FIGURE 28
15. Replace the bowl by pushing it into its seating.
16. Fasten the bowl in place by tightening the knobs (FIGURE 23) and the locking bar (FIGURE 21).
17. Replace the tap, remembering to smear both is seating in the bowl and the seals with food grade 
lubricant 
18. Remove the drip tray (L1) by rotating it 
slightly and pulling it outwards (FIGURE 
29).
Wash all the parts carefully and 
reassemble it by following the prior 
operations, remembering to re-insert the 
condensation discharge pipe (M1) in its 
seating.
FIGURE 29
A
B
C
D
A
B