Instruction manual

16
p) Remove the cap (T) fitted with the CIP device (fig. 26).
q) Remount the normal cap (I).
r) As soon as all the cleaning procedures are complete,
repeat the same operations, in the same order, for the
other tank/s.
11.2 - Cleaning and sanitising operations using the normal
method
(MONTHLY)
Fig. 26
Attention !!
Unlike with the cleaning operations using the CIP
method, the following cleaning operations must be
carried out with the machine disconnected from the
electricity supply, as described earlier.
a) Empty the tank of the remaining drinks product and
switch off the main switch (M).
b) Lift the cover (G) and remove the CO
2
feeder hose (W)
from its connector (X) located on the tank, pushing
towards the inside of the connector lightly first of all, then
pulling the hose outwards (fig. 27).
c) Remove the safety/locking pin (Y) by pulling it upwards
(fig. 28).
d) Slide the locking bar (Z) out to release the tanks fully in
order to facilitate their disassembly (fig. 29).
e) Unscrew the knobs (A1) to lower the tanks slightly and
then slide the tank out of its seating, pulling it outwards
(fig. 30).
Fig. 27
Fig. 28
Fig. 29
Fig. 30
Z