Instruction manual
10
Both functions have now been programmed to start
automatically.
When the red LED next to the
button (O) lights up,
this means the functions are running in the automatic mode.
To switch from automatic to manual mode, press again the
button (O) (the relevant red LED will go out, thus
confirming that the machine is set to be operated manually).
8.3 - Variations in the time display (twenty-four or twelve
hour clock) and the temperature display (°C or °F)
The electronic system in the Ice Frost Manual 2.2 is set
during the production phase to indicate the time in the
twenty-four hour clock and the temperature in degrees
Celsius.
However, there is an electronic key which can be used to
vary these values and express the time in the twelve hour
clock and the temperature in degrees Fahrenheit.
To do so, proceed as follows.
Starting with the machine switched off, hold down the
button (N) and at the same time, switch on the machine
using the main switch “M”.
The number “24” will flash on the display. If the user presses
the
(O) button, the display will switch to “12”. At this
point, the variation must be confirmed by the MODE button
being pressed.
Then the symbol “C” (degrees Celsius) will start to flash on
the display. When
(O) is pressed, the symbol “F”
(degrees Fahrenheit) will appear and this must be confirmed
by pressing the MODE button.
Fig. 10