Service manual

61 TD 204
Trouble RemedyProbable Cause
E. Expansion
valve failure
(will not pull
down).
E. Tighten bulb,
replace as
needed, See
check-out
procedure.
CUBER
REMAINS IN
THE HARVEST
CYCLE
SUCTION LINE THERMISTOR OPEN
(STARTS IN HARVEST)
A. Loose
connection
at the circuit
board.
A. Tighten or
reconnect.
B. Test
thermistor.
B. Replace if out of
range.
PROXIMITY SWITCH LIGHT OUT
C. Loose wire
connection
at circuit
board.
C. Tighten, reattach
wire.
D. Proximity
switch
defective,
see
check-out
procedure.
D. Replace as
needed.
E. Water
curtain
stuck,
curtain
frozen to ice
on
evaporator.
Curtain hung
on water
pan,
proximity
switch out of
range.
E. Check and
adjust as
needed.
PROXIMITY SWITCH LIGHT ON