Service manual

37 TD 204
Error LED (contd)
D5
Red LED
FlashĆ
ing,
1/sec
CONDENSER OPEN
THERMISTOR CIRCUIT (Air
Cooled only) Ć Thermistor
open / broken wire / poor
connection. Ice Maker is
SHUT DOWN. Consult serĆ
vice manual (Diagnostic
Section) for trouble shooting
guide.
D5
Red LED
FlashĆ
ing,
1/sec
CONDENSER LOW TEMĆ
PERATURE CONDITION. Ć
Condenser midpoint reachĆ
es 2.2°C Ć Ice Maker is
SHUT DOWN.
D5
Red LED
FlashĆ
ing,
1/sec
CONDENSER HIGH TEMĆ
PERATURE SAFETY SHUT
DOWN
Reset Operation
When Cuber is functionally shut down and red Error LED is op-
erational, the Cuber power switch must be turned off for 5 seconds
and returned to the on position to reset the circuit board and allow
the Cuber to restart operation.
Voltage Selector Switch
1. Selector bar in center position, switch is open. Product
is inoperative
2. Selector bar in down position, selection is for 115
VAC.
3. Selector bar in up position, selection is for 230 VAC.
Stacking Cable
When stacking the I series cuber the connecting cable (connecting
the two (2) circuit boards) will allow: When the bottom product
shuts off on the full bin signal (or any error code) the top product will
finish the cycle it is in and will also shut down. The I series should
never be stacked more than two high.
Test Plug
Board manufactures check point.
DO NOT ATTEMPT ANY VOLTAGE CHECKS AT THESE PINS.