Service manual

13 TD 204
Should a different thickness of the bridge be desired, it will be re-
quired to adjust the ice thickness POT, located on the circuit
board, as follows:
1. Thinner Bridge turn the ice thickness pot adjust-
ment screw CW one full turn. Allow two cycles
before determining if additional adjustments are re-
quired.
2. Thicker Bridge turn the ice thickness pot adjusting
screw CCW one full turn. Allow two cycles before
determining if additional adjustments are required.
NOTE: Never judge the thickness of the ice from the first
batch of the ice produced the first cycle is a bal-
ance cycle. Always wait for the second cycle before
making any adjustments.