IMI CORNELIUS REMCOR INC g 500 REGENCY DRIVE g GLENDALE HEIGHTS, IL 60139--2268 Telephone (800) 551--4423 Facsimile (800) 519--4423 Operator’s Manual ICE/BEVERAGE DISPENSER Models: ENDURO-150 6 Valve and ENDURO-100 IMPORTANT: TO THE INSTALLER. It is the responsibility of the Installer to ensure that the water supply to the dispensing equipment is provided with protection against backflow by an air gap as defined in ANSI/ASME A112.1.
TABLE OF CONTENTS Page MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 DAILY (OR AS REQUIRED) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . WEEKLY (OR AS REQUIRED) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1 MONTHLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MAINTENANCE The following dispenser maintenance should be performed at the intervals indicated: DAILY (or as required) Remove foreign material from vending area drip tray to prevent drain blockage. WEEKLY (or as required) Clean vending area. Check for proper water drainage from the vending area drip tray. MONTHLY Clean and sanitize the hopper interior and beverage system, if applicable (see CLEANING INSTRUCTIONS). START-UP & OPERATING INSTRUCTIONS Fill the hopper with ice.
DISPENSER 1. CLEANING EXTERIOR SURFACES Important: Perform the following daily. A. Remove the cup rest from drip tray. B. Wash the drip tray with soap solution. Rinse with clean water and allow solution to run down the drain. C. Wash cup rest with soap solution and rinse in clean water. Install the cup rest into the drip tray. D. Clean all exterior surfaces with soap solution and rinse in clean water. 2. COLD PLATE INSPECTION BEFORE CLEANING A. Remove splash panel. B.
BEVERAGE SYSTEM (IF APPLICABLE) WARNING: Disconnect Power Before Cleaning! Do not use metal scrapers, sharp objects or abrasives on the ice storage hopper, top cover and the agitator disk, as damage may result. Do not use solvents or other cleaning agents, as they may attack the plastic material. Soap solution - Use a mixture of mild detergent and warm (100 degrees F) potable water. Sanitizing solution - Use 1/2 ounce of household bleach in 1 gallon of potable water.
n. B. 92096 Discard the tank of sanitizing solution and reconnect the product (syrup or pre-mix) tanks. Operate the valves until all sanitizer has been flushed from the system and only product (syrup or pre-mix) is flowing. Sanitize syrup lines, B-I-B Systems a. Remove all the quick disconnects from all the B-I-B containers. b. Fill a suitable pail or bucket with soap solution. c. Submerge all disconnects (gas and liquid) in the soap solution and then clean them using a nylon bristle brush.
TROUBLESHOOTING IMPORTANT: Only qualified personnel should service internal components or electrical wiring. WARNING: If repairs are to be made to a product system, remove quick disconnects from the applicable product tank, then relieve the system pressure before proceeding. If repairs are to be made to the CO2 system, stop dispensing, shut off the CO2 supply, then relieve the system pressure before proceeding.
Trouble Probable Cause BEVERAGES NOT SWEET ENOUGH. BEVERAGES NOT COLD (UNITS WITH BUILT-IN COLD PLATE). A. Empty syrup tank. B. Faucet brix requires adjusting. A. Unit standing with no ice in hopper -- no ice in cold plate cabinet. Contact your local syrup or beverage equipment distributor for additional information and troubleshooting of beverage system.
PARTS LIST / EXPLODED VIEW 7 92096
19 52 57 5 67 67 87 96 1 26 68 63 2 46 88 32 79 66 90 4 44 50 91 81 49 92 64 25 67 94 74 48 62 80 69 56 39 21 30 74 24 94 51 6 72 61 10 54 73 88 60 72 74 72 72 17 58 53 88 7 86 84 34 70 95 14 13 34 22 12 93 88 15 77 82 59 47 8 55 23 83 FIGURE 1.
CABINET SECTION PARTS LIST Index No. Part No.
CABINET SECTION PARTS LIST (CONT’D) 33 Not Used 34 71010 35 Not Used 36 Not Used 37 Not Used 38 Not Used 39 620019701 40 Not Used 41 Not Used 42 Not Used 43 Not Used 44 **51859 45 Not Used 46 51891 47 ***51908 Plug (120 Volt Models Only) 48 **52876 Gasket, Motor Shaft 49 620500901 50 53168 Cover, Ice Chute 51 53241 Access Cover (Cold Plate Models Only) 52 53227 Agitator Disk 53 52878 Merchandiser, Black (ED 150) 52999 Merchandiser, Gray (ED 150) 15756 Merch
CABINET SECTION PARTS LIST (CONT’D) 65 Not Used 66 **70048 67 70056 Washer, No. 10, .219 I.D. 68 70067 Washer, .218 I.D. 69 70076 Hex Nut, No. 8-32 Insert, Threaded, No. 8-32 Washer, .255 I.D. 70 70104 71 Not Used 72 70171 Machine Screw, Phil Truss Hd, No. 8-32 By 3/8-In. Long 73 70178 Machine Screw, Phil Truss Hd, No. 8-32 By 1/2-In. Long Sheet Metal Screw, Phil Truss Hd, No. 8 By 1/2-In.
5 4 11 17 7 1 13 15 16 2 9 12 14 18 10 RIGHT SIDE FRONT FIGURE 2. ELECTRICAL BOX ASSEMBLY EXPLODED VIEW ELECTRICAL BOX ASSEMBLY Item No. Part No.
SOLENOID ASSEMBLY 9 4 11 5 14 3 6 5 12 13 10 15 8 7 1 2 FIGURE 3. SOLENOID ASSEMBLY Item No. Part No. 1 28173 Arm, Gate Lift 2 50754 Bearing, Gate Arm 3 32957 Solenoid, 120 Volts 33397 Solenoid, 220-240 Volts 4 28172 Plate, Solenoid Mounting 5 50752 Isolator 6 70015 Hex Nut, No. 10-32 7 51689 Locktite 8 70162 Screw, No. 8-32 By 1/4-In. Long 9 50705 Tie Cable 10 70165 Screw, No. 8-32 By 5/8-In.
DRAIN TO COLD PLATE DRAIN ELBOW 1 3 4 1 TO COLD PLATE DRAIN ELBOW 1 1 2 1 3 FIGURE 4. COLD PLATE DRAIN FOR Z STYLE UNITS Item No. Part No.
WARRANTY IMI Cornelius Inc. warrants that all equipment and parts are free from defects in material and workmanship under normal use and service. For a copy of the warranty applicable to your Cornelius, Remcor or Wilshire product, in your country, please write, fax or telephone the IMI Cornelius office nearest you. Please provide the equipment model number, serial number and the date of purchase. IMI Cornelius Offices AUSTRALIA D P.O.
IMI CORNELIUS INC.