ADJUST WATER-TO-SYRUP RATIO
Separator
Water-To-Syrup
ratio cup
Figure 1.
1. Remove valve cover and install syrup separator over the diffuser and through the nozzle.
2. Hold cup under valve and dispense beverage for a specific time (i.e. 2 seconds).
NOTE:Water and syrup must be cold before checking ratios.
3. Adjust carbonated water flow to the desired rate (such as 90 to 110 ml (3 to 3.75 oz.) per second).
4. Turn the flow adjuster 1/4 of a turn at a time and recheck the flow. To increase reading turn clockwise.
5. Set syrup flow adjuster to get the desired ratio.
6. Test the valve and adjust until a consistent ratio is delivered three consecutive times.
7. Repeat procedure for other valves
Valve Type
Manufacturer Maximum Operating Pressure
Portion Control
Cornelius 130 psi
Flowmatic 100 psi
Pushbutton
Cornelius 130 psi
Flowmatic 100 psi
Lever Type
Cornelius 130 psi
Flowmatic 100 psi
Autofill Lever
Cornelius 130 psi
Flowmatic 100 psi
Non-Electric
Cornelius 130 psi