Technical information
Installation Instruction for all Models of Drop-In and Free Standing Ice Cooled Dispensers
Publication Number: 166239001 - 8 - © 1994-2014, Cornelius Inc.
PREPARING FOR OPERATIONS
NOTE:: On Units Without Electrically Operated Valves, Skip Steps 1 & 2 Below
1. Plug transformer into electrical outlet. The 24V supply must be connected in the dispensing tower.
2. Turn the key-switch to the ON position. The ice-bin lid must be closed to allow the valves to operate.
3. Adjust the CO
2 regulators as indicated in the following chart:
4. Operate each valve until product is flowing.
5. Fill the bin with 32°F ice. Do not use ice taken directly from a freezer.
6. Adjust the brix (water-to-syrup ratio) for post-mix valves.
7. Set the flow rate for pre-mix valves.
Post Mix
Regulator Pressure Setting
Primary (Carbonator) 90 - 120 PSI
Secondary, Sugared Syrup Tank 55 PSI
Secondary, Diet Syrup Tank 8 - 12 PSI
Secondary, B-I-B 60 PSI
Basic pressure shown is based on ambient temperature of 72°F. Use a Cornelius Pre-Mix slide rule for exact calcula-
tions.
Pre-mix
Basic Pressure 47 PSI
For each 10 ft. of horizontal tubing between tank and
dispenser
Add 1 PSI
For each 2 ft. of elevation
Add 1 PSI
For each tank per flavor over 3 tanks
Add 1 PSI