Technical information

Alta 1522 Drop-in Dispenser Installation Instructions
Publication Number: 741200028INS - 10 - © 2013-2014, Cornelius Inc.
ADJUST WATER-TO-SYRUP RATIO
Figure 1. Water to Syrup Ratio Adjustment
1. Remove valve cover and install syrup separator over the diffuser and through the nozzle.
2. Hold cup under valve and dispense beverage for a specific time (i.e. 2 seconds).
NOTE: Water and syrup must be cold before checking ratios.
3. Adjust carbonated water flow to the desired rate [such as 2 to 3 oz. (59 to 88.5 ml) per second].
4. Turn the flow adjuster 1/4 of a turn at a time and recheck the flow. To increase reading turn clockwise.
5. Set syrup flow adjuster to get the desired ratio.
6. Test the valve and adjust until a consistent ratio is delivered three consecutive times.
Separator
Water-To-Syrup
Ratio Cup