Service manual

Ice Portion Size Adjustmeat
Located in the rear of the electrical box assembly, you will find the ICE PORTION SIZE ADJUSTMENT
KNOB. Turn the ICE PORTION SIZE ADJUSTMENT KNOB
to
the left (counterclockwise) for less ice
dispensed
or
turn the knob
to
the right (clockwise) for more ice dispensed.
Adjust the ice portion size as instructed in this paragraph.
Time Delav Retween Dispensed Ice Portions Adjustment
Inside the electrical control box assembly, you will find a time delay between dispensed ice portions TIME
DELAY ADJUSTMENT SCREW (blue plastic square box with screw driver
slot
in center) on the portion control
board. The time delay between dispensed ice portions may be adjusted from between
0
and 60-seconds. Turn
the TIME DELAY ADJUSTMENT SCREW for more or less time between dispensed ice portions as indicated by
adjustment marks on the control board next
to
the blue plastic square box. This makes it inconvenient
to
fill
the
ice chest from the dispenser.
Adjust the time delay between ice portions as instructed in this paragraph.
OPERATION
NOTE: If the dispenser has not vended ice for
two
hours, an automatic agitation cycle
will
be initiated
by the solid-state portion control and
will
last approximately
two
seconds to stir up the ice in the ice
bln hopper.
1. Referring to
ELECTRICAL REQUIREMENTS,
connect electrical power
to
the dispenser.
I
Dispense WenseL
With the MANUAUPORTION CONTROL SWITCH placed in the ”MANUAL“ position, pressing the Ice Dis-
pense Switch on the electrical box assembly front panel will activate the dispenser and ice will be dispensed
continuously until the switch is released.
If
the MANUAUPORTION CONTROL SWITCH is placed in the “POR-
TION” position, a set time of approximately 112
to
20-seconds (adjustable) will be established and pressing the
Ice Dispense Switch will dispense that pre-set portion of ice.
Kev Op-d Dispensars,
A special key must be used
to
activate the dispenser to dispense ice. With the MANUAUPORTION CONTROL
SWITCH placed in the “MANUAL” position, activating the dispenser key switch on the electrical control box front
panel will dispense ice continuously until the key switch is released.
If
the MANUAUPORTION CONTROL
SWITCH is placed in the “PORTION” position, a set time of approximately
1/2
to
20-seconds (adjustable) will
be established and activating the dispenser key switch will dispense that pre-set portion of ice.
Card Operated DiSpenseL
A special plastic card must be used
to
activate the dispenser
to
dispense ice. With the MANUAUPORTION
CONTROL SWITCH placed in the “MANUAL” position, activating the dispenser with the special plastic card will
dispense ice continuously until the card is removed.
If
the MANUAUPORTION CONTROL SWITCH is placed
in the “PORTION” position, a set time of approximately 1/2 to 20-seconds (adjustable) will be established and
activating the dispenser with the special plastic card will dispense that pre-set portion of ice.
16
195280
1
10