Service manual
Lipton Brewed Iced Tea Training, Installation, & Service Manual
May 7, 2002 - 45 630460171
EXCESSIVE BURPING (CON-
STANT DISCHARGE FROM
BURP TUBE)
• Temperature too high. • Re-adjust thermostat (see no Hot
water).
WATER IN BOTTOM OF
BREWER
• Examine for leaks.
• Air ejector leaking.
• Repair or replace leaking component.
• Repair or replace.
• Check to see that the ball in the air
ejector is not stuck. If the ball is
stuck, homogeneity problems will
result. One symptom of the ball
being stuck can be air pockets going
out through the dispense nozzle.
• The fitting should be finger tight only.
WATER UNDER BREWER • Water temperature too high. • Measure and adjust as necessary.
• Unit will shut off heater relay if water
temperature exceeds 192
°F. A high
temperature message will appear on
the data mode screen. To turn the
heater relay back on (two things are
required), first the tank temperature
must drop below 192°F and then the
operator needs to press Run to put the
unit back into operation (See advi-
sory).
CLOUDY TEA • Air injector not venting.
• Low brewing temperature.
• Exceeding capacity of unit.
• Repair or replace.
• Check to see that the ball in the air
ejector is not stuck. If the ball is
stuck, homogeneity problems will
result. One symptom of the ball
being stuck can be air pockets going
out through the dispense nozzle.
• The fitting should be finger tight only.
• See No Hot Water.
Trouble Probable Cause Troubleshooting & Repair
Procedures