NO HOT WATER (CONT.) • No water entering tank.
• No power to control board.
• Defective Hot water valve.
• Check water supply.
• Plugged water filter.
• See “defective hot water valve”
• Same coil used for Hot, Cold, and
Sweetener Valve.
• Utilizes standard piston and sleeve
flow control.
• The Ohm resistance for the coil is
approximately 6 Ohms.
• Check power supply and 24V trans-
former.
• Uses two standard (80 VA) beverage
transformers.
• Voltage output should be approxi-
mately 27 VAC. with no load. Under
load the output should be between 22
and 25 VAC. No lower than 22 VAC.
• As viewed from the rear. The left
transformer supplies power to the
KIP valves and flow control valves
(power is only switched through the
control module).
• The right transformer supplies power
to the board and for the pump motor.
• Check adjustment.
• Check coil resistance.
• Same coil used for Hot, Cold, and
Sweetener Valve.
• Utilizes standard piston and sleeve
flow control.
• The Ohm resistance for the coil is
approximately 6 Ohms.
• Check for restrictions.
• Check for power to coil.
• As viewed from the rear. The left
transformer supplies power to the
KIP valves and flow control valves
(power is only switched through the
control module).
Trouble Probable Cause Troubleshooting & Repair
Procedures