Service manual
Lipton Brewed Iced Tea Training, Installation, & Service Manual
May 7, 2002 - 33 630460171
Rinse Cycle Program
Yes
Yes
Yes
Yes
Yes
Rinse
Cycle
Blink LED & warning,
flash backlight for 2 seconds,
flush deadlegs for 10 seconds
Wait 90 seconds
Blink LED & warning,
flash backlight for 2 seconds,
flush deadlegs for 10 seconds
Blink LED & warning,
flash backlight for 2 seconds,
flush deadlegs for 10 seconds
Blink LED & warning,
flash backlight for 2 seconds,
flush deadlegs for 10 seconds
Blink LED & warning,
flash backlight for 2 seconds,
flush deadlegs for 10 seconds
Wait 80 seconds
Wait 80 seconds
Wait 80 seconds
No
No
No
Is water
temperature
above 160
degrees F
and disp valve
open?
Is water
temperature
above 160
degrees F
and disp valve
open?
Is water
temperature
above 160
degrees F
and disp valve
open?
Is water
temperature
above 160
degrees F
and disp valve
open?
Is water
temperature
above 160
degrees F
and disp valve
open?
Is dispense
valve open?
Do a 5 second pour
to reprime the lines
Save this rinse time to EE
Clear flag indicating "rinse required"
Go to run mode
No
No
No
2