Service manual
Lipton Brewed Iced Tea Training, Installation, & Service Manual
630460171 - 20 May 7, 2002
FIGURE 1 Installation Procedure
The following sections include the brewer’s installation and set up procedures.
FILLING THE WATER TANK
1. Install the Water Filter supplied between the incoming water line and the
brewer.
2. A Water Booster Kit should be added if the water pressure to the unit is
below 40-psi static pressure or 35-psi flowing pressure. A Water Pres-
sure Regulator should be added if the static pressure is above 70-psi.
3. Connect the 3/8-inch water filter outlet to the water inlet fitting on the
back of the brewer. Connect sweetener BIB to the 1/4-inch sweetener in-
let tube.
4. Connect the Power Cord to a dedicated 115-volt, 15-amp circuit. Turn
the ON/OFF power switch located on the back of the unit to the ON po-
sition.
5. Slide open the top front access door and press the (-) key for 5 seconds
to unlock the key pad.
6. Press Menu key until Enter SET-UP? is displayed.
7. Press and hold the STOP key and then press the RINSE key to enter
SET-UP.
8. Press (>) and then the (#) key to enter TANK STATUS and then read
the flash screen. The Hot Water Tank screen will be displayed. It will
read Is Set To EMPTY.