Service manual
Lipton Brewed Iced Tea Training, Installation, & Service Manual
630460171 - 14 May 7, 2002
PUSH KEY Quick Reference
Push Key
Push Key Function
LANGUAGE Toggles between English and Spanish
MENU Scrolls to main menu functions of DATA, SET TIME, ADJUST STRENGTH, AND SERVICE
RINSE Initiates RINSE function
STOP Will stop and prevent further dispensing action (heater stays on)
RUN Initiates normal dispense and operational functions.
MENU Quick Reference
MENU Option
MENU Option Function
DATA Selected operational data may be viewed.
SET TIME Clock and Rinse times may be set.
ADJUST STRENGTH Tea strength may be adjusted to a range of +/- 5 percent of as-installed strength.
SERVICE Various service screens (as noted below) may be viewed.
Service Mode is entered by pressing and HOLDING Stop Key and then pressing Run Key.
SET-UP Various set-up screens (as noted below) may be viewed.
Set-Up Mode is entered by pressing and HOLDING Stop Key and then pressing Rinse Key.
SERVICE Quick Reference
SERVICE Screens
SERVICE Screen Function
Display Errors Error displays may be scrolled by pressing (>) or (<) Keys.
Tea Pump State Tea extract flow may be initiated by pulling spigot handle.
Sweetener Valve State Sweetener flow may be initiated by pulling spigot handle.
Hot Brew Valve(s) State Hot brew water flow may be initiated by pulling spigot handle.
Rinse Valve State Rinse water flow may be initiated by pulling spigot handle.
Cold Water Valve State Cold water flow may be initiated by pulling spigot handle.
Tea Bag Status OK or Soldout
Sweetener Status OK or Soldout
Hot Water Temp In degrees C or F, press (+) or (-) Key To Flip.
Heater Relay Status On or Off press (+) or (-) Key To Flip.
Motor Volts Volts DC
Normal Pour Dispensed drink flow may be initiated by pulling spigot handle
SET-UP Quick Reference
SET-UP Screens
INSTALL Screen Function
Tank Status Operator is able to fill the tank and set the tank status of empty or full.
System Type Single or double spigot configuration is displayed.
Set-Up Tea Extract Operator may prime the tea extract lines and run a 10 seconds calibration pour.
Tea strength may be adjusted to a range of +/- 20 percent of factory set pump speed.
Set-Up Sweetener Operator may set sweetened or unsweetened operation, prime the sweetener lines, and
run a 10 second calibration pour.