Service manual
Lipton Brewed Iced Tea Training, Installation, & Service Manual
630460171 - 12 May 7, 2002
4. Press (#) to enter or exit the sub-modes and follow the displayed instructions.
TANK STATUS
The heater tank may be filled with water in this sub-mode. Once water flows
from the spigot nozzle then change the tank status to FULL.
SYSTEM TYPE
The system configuration is displays a double or single spigot.
SET-UP TEA SYRUP
Follow the display instructions to prime the tea extract lines, adjust strength
and dispense a 10 second calibration pour. This is used to calibrate the
amount of tea to be dispensed during a normal pour sequence (approxi-
mately 1 gram per second).
NOTE: Tea extract may accumulate in the mix chamber. Several dis-
penses may be required for tea extract to start flowing from the noz-
zle.
The allowed strength accustomed range is +/- 20%. Each press of the (+) or
(-) keys will change the tea strength by 1% until the 20% maximum change
is reached.
SET-UP SWEETENER
Pressing the (+) or (-) keys will toggle the sweetener valve from OFF (dis-
abled)) and ON. If OFF is selected, the next step is skipped.
Follow the display instruction to prime the sweetener line and to dispense a
10 second calibration pour. This is used to calibrate the amount of sweetener
to be dispensed during a normal pour sequence.
CAUTION: Ensure there is water in the heater before
the heater relay is turned ON. Otherwise the heater will
fail and it will have to be replaced.