Service manual
Lipton Brewed Iced Tea Training, Installation, & Service Manual
May 7, 2002 - 11 630460171
TEA BAG SOLD OUT STATE
This screen displays the current state of the Tea Extract Bag (Sold Out or
OK).
SWEETENER SOLD OUT STATE
This screen displays the current state of the Sweetener (Sold Out or OK).
This screen is skipped if unit is installed as unsweetened.
HOT WATER TEMPERATURE
This screen displays the current hot water heater tank temperature. Pressing
the (+) or (-) key will toggle the display between degrees Fahrenheit and
degrees Celsius.
HEATER RELAY STATE
This screen displays the current state of the hot water heater safety relay
(ON/OFF). Pressing the LANGUAGE key will toggle the state between ON
and OFF. When leaving this screen the safety relay will toggle to ON, unless
an overriding error is present.
MOTOR VOLTS
This screen displays the DC voltage available to drive the tea pump.
NOTE: 30 to 40 Volts DC range. Usually, approximately 37 Volts will
be displayed.
NORMAL POUR
Pull the dispense lever to dispense finished product.
SET-UP mode
1. Press menu until Enter SET-UP is displayed.
2. Press and hold the STOP key and then press the RINSE key
3. Press (>) to advance to the following sub-modes.