4. Press (#) to enter or exit the sub-modes and follow the display instruc-
tions.
DISPLAY ERRORS
Displays most recent error first Press (>) to advance through all errors.
TEA PUMP STATE
This screen displays the current state of the Tea pump (ON/OFF). Pull the
dispense lever to start the flow of tea. Release the dispense lever to stop the
flow of tea.
SWEETENER VALVE STATE
This screen displays the current state of the Sweetener valve drive (ON/OFF
or DISABLED). Pull the dispense lever to start the flow of sweetener.
Release the dispense lever to stop the flow of sweetener.
NOTE: If the brewer is installed as unsweetened, the valve is overrid-
den and locked out, and the controller skips over this function in Ser-
vice mode.
HOT BREW WATER VALVE STATE
This screen displays the current state of the Hot water valve drive (ON/
OFF). Pull the dispense lever to start the flow of hot water. Release the dis-
pense lever to stop the flow of hot water.
Note: The Hot water valve drive operates both the input and output
Hot water valves at the same time.
RINSE WATER VALVE STATE
This screen displays the current state of the Rinse water valve drive (ON/
OFF). Pull the dispense lever to start the flow of hot water. Release the dis-
pense lever to stop the flow of hot water.
COLD WATER VALVE STATE
This screen displays the current state of the Cold water valve drive (ON/
OFF). Pull the dispense lever to start the flow of cold water. Release the dis-
pense lever to stop the flow of cold water.