Service manual

Lipton Brewed Iced Tea Training, Installation, & Service Manual
May 7, 2002 - 5 630460171
Do not activate the heater until the water tank is full.
Rinse must be performed at least once every 24 hours or the brewer will lock out
and will not dispense product.
The heater tank contains no replaceable parts. The entire heater tank must be
replaced if service is required.
Warning Battery Life: Disconnecting the power supply or turning the power
switch off for longer than 48 hours will result in a service call to reprogram the
dispenser. The battery will recharge itself when the power is restored to the
board.
CLEANING AND SANITATION PRACTICES
It is imperative that the daily cleaning procedures, hot water flush, and monthly sanitizing
procedures be followed as outlined in chapter 4.
WARNING: Failure to follow the scheduled cleaning
and sanitizing procedures shown in chapter 4 may
result in the growth of potentially harmful bacteria in
the dispensed tea product.