Programming instructions
9 1409
Table 5. “TOTALS” (DISPLAYED CYCLES AND HOURS TOTALS) MENU
TOTALS MENU COMMANDS DESCRIPTION
COMP HRS COMPRESSOR RUN HOURS
COMP CYC COMPRESSOR CYCLES X100
DFSTYC1 DEFROST SIDE 1 CYCLES
DFSTYC2 DEFROST SIDE 2 CYCLES
BLDRCYC1 BLENDER SIDE 1 CYCLES X100
BLDRCYC2 BLENDER SIDE 2 CYCLES X100
SOLDOUT 1 SOLDOUT SYRUP SIDE 1
SOLDOUT 2 SOLDOUT SYRUP SIDE 2
BMTRHRS1 BEATER MOTOR 1 HOURS
BMTRHRS2 BEATER MOTOR 2 HOURS
PWR ON POWER ON HOURS
AUTO ON 1 AUTO SIDE 1 HOURS
AUTO ON 2 AUTO SIDE 2 HOURS
ERR HRS 1 ERROR SIDE 1 HOURS
ERR HRS 2 ERROR SIDE 2 HOURS
SLEEP HRS SLEEP MODE HOURS
SYR MIN 1 SYRUP MINUTES (SIDE 1)
SYR MIN 2 SYRUP MINUTES (SIDE 2)
Table 6. DISPLAYED ERROR CONDITIONS
ITEMS AFFECTED BY ERROR
MESSAGE
DISPLAY ERROR
BEATER
MOTOR 1
BEATER
MOTOR 2 REFRIG 1 REFRIG 2
Motor 1 Low Current, < 109,
Sensed on motor one
OFF OFF
Motor 2 Low Current, < 109,
Sensed on motor two
OFF OFF
Motor 1 High current > 255,
Sensed on motor one
OFF OFF
Motor 2 High current > 255,
Sensed on motor two
OFF OFF
REFRIG Maximum Run Time on compressor OFF OFF OFF OFF
SYRUP 1 Syrup Out Side One OFF
SYRUP 2 Syrup Out Side Two OFF
CO
2
OUT CO
2
Out OFF OFF
H
2
O OUT H
2
O Out *OFF *OFF
SENSOR 1 Temp Sensor Inlet One OFF OFF OFF OFF
SENSOR 2 Temp Sensor Inlet Two OFF OFF OFF OFF
SENSOR 3 Temp Sensor Outlet OFF OFF OFF OFF
*The refrigeration system and carbonator shall continue to operate for 1.5 minutes after a water pressure loss has been
detected. If water pressure loss continues beyond 1.5 minutes, the refrigeration system and carbonator will stop.