Programming instructions

4
1409
3. Press ‘‘CANCEL DEFROST’’ (ADVANCE) switch to
advance hours on display to desired hour. Press
‘‘DEFROST’’ (SELECT) switch to lock in hour on
display.
4. After hour (time of day) has been locked in on mes-
sage display, minute numbers will be flashing on
display. Press ‘‘CANCEL DEFROST’’ (ADVANCE)
switch to advance minute numbers to desired min-
utes (time of day). Press ‘‘DEFROST’’ (SELECT)
switch to lock in minutes (time of day) on display.
5. Press ‘‘ERROR RESET’’ switch two times to exit
from MENU SELECTIONS.
PROGRAMMING ‘‘WAKE UP’’ (WAKE UP TIME)
INTO UNIT
‘‘WAKE UP’’ (WAKE UP TIME) may be programmed into
Unit to occur any time of the day to wake Unit up (return
to normal operation) after ‘‘sleep time’’ has occurred.
Program ‘‘WAKE UP’’ into Unit as follows:
1. Refer to PROGRAMMING MAIN MENU SELEC-
TIONS ONTO MESSAGE DISPLAY and bring up
‘‘WAKE UP’’ on message display. Press ‘‘DE-
FROST’’ (SELECT) switch to lock in on selection.
2. Press ‘‘CANCEL DEFROST’’ (ADVANCE) switch to
bring up flashing hour number on display.
3. Press ‘‘CANCEL DEFROST’’ (ADVANCE) switch to
advance hours on display to desired hour. Press
‘‘DEFROST’’ (SELECT) switch to lock in hour on
display.
4. After hour (time of day) has been locked in on mes-
sage display, minute numbers will be flashing on
display. Press ‘‘CANCEL DEFROST’’ (ADVANCE)
switch to advance minute numbers to desired min-
utes (time of day). Press ‘‘DEFROST’’ (SELECT)
switch to lock in minutes (time of day) on display.
5. Press ‘‘ERROR RESET’’ switch two times to exit
from MENU SELECTIONS.
PROGRAMMING POINT OF SALE MESSAGE
DISPLAY
(see Figure 2 and Table 4)
NOTE: Point of sale display messages may be
turned off by placing No. 1, No. 2, and No. 3
switches on master circuit board (see Figure 2 and
Tables 2 and 4) DIP SWITCH assembly in appropriate
positions.
Five point of sale display messages are available to
choose from and may be programmed by placing No. 1,
No. 2, and No. 3 switches on DIP SWITCH assembly on
master circuit board in appropriate positions. Refer to
Figure 2 and Tables 2 and 4 and program desired point
of sale display message which will be displayed on mes-
sage display.
ADJUSTING ‘‘VIS SET’’ (PRODUCT VISCOSITY)
OF DISPENSED PRODUCT
Adjusting ‘‘VIS SET’’ (PRODUCT VISCOSITY) deter-
mines what product consistency of the dispensed prod-
uct will be present in each freeze cylinder. Adjust ‘‘VIS
SET’’ (PRODUCT VISCOSITY) of the dispensed product
as follows:
1. Refer to PROGRAMMING MAIN MENU SELEC-
TIONS ONTO MESSAGE DISPLAY and bring up
‘‘VIS SET’’ on message display.
2. Press ‘‘DEFROST’’ (SELECT) switch to bring up
numbers on message display.
NOTE: The direction of arrows (Ơơ) on message
display indicates which set of numbers belongs to
which freeze cylinder. A No. 4 setting indicates the
thinnest product consistency of dispensed product
and a No. 12 setting indicates the thickest consisten-
cy of product dispensed.
3. Press ‘‘CANCEL DEFROST’’ (ADVANCE) switch.
The leftside freeze cylinder viscosity number will
be flashing on message display.
4. Press ‘‘CANCEL DEFROST’’ (ADVANCE) switch to
advance viscosity number to desired setting. Press
‘‘DEFROST’’ (SELECT) switch to lock in viscosity
setting. The rightside freeze cylinder viscosity
number will now be flashing.
5. Press ‘‘CANCEL DEFROST’’ (ADVANCE) switch to
advance viscosity number to desired setting. Press
‘‘DEFROST’’ (SELECT) switch to lock in viscosity
setting.
6. Press ‘‘ERROR RESET’’ switch two times to exit
from MENU SELECTIONS.
‘‘VIS READ’’ (ACTUAL VISCOSITY READOUT)
OF PRODUCT IN FREEZE CYLINDERS
‘‘VIS READ’’ (ACTUAL VISCOSITY READOUT) may be
brought up on message display to actually read the vis-
cosity (product consistency) of the product in the freeze
cylinders while the Unit is in operation. Bring ‘‘VIS READ’’
up on message display as follows:
1. Refer to PROGRAMMING MENU SELECTIONS
ON MESSAGE DISPLAY and bring up ‘‘VIS READ’’
of product in freeze cylinders.
2. Press ‘‘DEFROST’’ (SELECT) switch to bring up
actual viscosity readout of product in each freeze
cylinder.
3. Press ‘‘ERROR RESET’’ switch two times to exit
from MENU SELECTIONS.