Service manual
560001279SER
40
‘‘SYRUP PRIME’’ SWITCHES
The ‘‘SYRUP PRIME’’ switches, located on the control panel, are touch-type switches and require only pressing
to activate. The ‘‘SYRUP PRIME’’ switches are used only when filling the syrup systems sold-out floats during
syrup replenishing, syrup flavor changeover, or sanitizing the syrup systems.
‘‘BLEND ON/OFF’’ SWITCHES
The ‘‘BLEND ON/OFF” switches, located on the control panel, are touch-type switches and require only
pressing to activate. These switches are used to fill the product blender tanks after the sold-out floats have
been filled using the ‘‘SYRUP PRIME’’ switches. After the product blender tanks have been filled, the “BLEND
ON/OFF” switches may be pressed again to prevent more product from entering the product blender tanks
during BRIX test. The “ON” and “BLEND ON/OFF” switches must be pressed to operate the freeze cylinders
beaters and refrigeration system during normal operation.
‘‘MOTOR’’ SWITCHES
The ‘‘MOTOR’’ switches, located on the control panel, are touch-type switches and require only pressing to
activate. These switches are used to operate the freeze cylinders beaters with no refrigeration during sanitizing.
“ON’’ SWITCHES
The ‘‘ON’’ switches, located on the control panel, are touch-type switches and require only pressing to activate.
These switches are used to operate the freeze cylinders beaters and refrigeration system after cylinders have
been filled with product. The freeze cylinders beaters and refrigeration system may be stopped by pressing the
‘‘OFF’’ switches.
‘‘OFF’’ SWITCHES
The ‘‘OFF’’ switches, located on the control panel, are touch-type switches and require only pressing to activate.
These switches are used to stop freeze cylinders beaters and refrigeration system.
‘‘ERROR RESET’’ SWITCH
‘‘ERROR RESET’’ switch, located on the control panel, is a touch-type switch and requires only pressing to
activate. The ‘‘ERROR RESET’’ switch is used to restore normal operation after error within Unit (indicated by
‘‘ERROR 1’’ or ‘‘ERROR 2’’ on message display) has been corrected.