Operating instructions
Page 17
C
Triton
3.2 Electrical Connections
A socket outlet with an earthing contact featuring a maximum protection of 16 amps is required.
The line voltage must always be within following tolerances: 230 VAC +6%/-10% / 50 Hz
Triton 150 Triton 350 Triton 700 Triton 2500
Power consumption in watts 540 920 / 1000
1)
1150 1550
1)
2/3 HP Version
4. Installation
The device must be installed by a trained service technician.
Please take care, that the socket for the unit is always accessible.
There is no user serviceable items inside the equipment.
If the power supply cable to the unit is damaged, it has to be replaced by the manufacturer, the service partner or any
other qualified person to avoid safety hazard.
4.1 Water Connection
Connecting only to drinkable water
Connect the device to a feed line with an inner diameter of 10 mm. We recommend using a water filter and a water
pressure regulator for the water input. To permit flushing of the filter, a T-piece should be mounted downstream of the
water pressure regulator. The water flow pressure should be 3 bar (mount control pressure gauge on water pressure
regulator). A flow rate of 560 litres / hour is required. Due to the high flow rate, it may be necessary to install several
water filters and water tubes in parallel.
4.2 CO
2
Connection
You will require a two-wire pressure regulator, 7 bar. Using tubing with an inner diameter of 4 mm, connect the
pressure regulator to the carbonator. Set the CO
2
-pressure to 3,5 to 4,5 bar.
The unit include a CO
2
-pressure switch to switch off the dispensing valves at a CO
2
-pressure less than 3 bar.
4.3 Connecting Soda Water and Still Water Premix/Postmix Syrup
Connect one tube with an inner diameter of 6 mm to each device connection. Connect the tube end to the correct
cooling coil inputs of the cooler circuit carbonator.
4.4 Connection of Still Water Control
For still water, one switching cable (1 x 0.75 mm
2)
per still water tap must run from the soda circuit carbonator to the
still water tap. The electronic control system is actuated via this cable. An addition cable from one of the still water
valves is necessery.
Alternativley, there are some units which are controlled by a pressure switch for the still water. It is recommended to
adjust the still water flow pressure to 3.2 bar and the switching point of the pressure switch to 4.2 bar. If a different
flow pressure is required the switching point of the pressure switch must be set 1 bar above the flow pressure.
Refer to the circuit diagram for the connection. The flow rate of the still water should be 170 ml in 4 to 5 seconds.
5. Putting into and out of Service
5.1 Putting into Service
Comply with the cleaning regulations defined by law before beginning each operation.