Unit installation
3 312022000
GENERAL INFORMATION
IMPORTANT: To the user of this manual - This manual is a guide for installing, operating, and
maintaining this equipment. Refer to Table of Contents for page location of detailed information
pertaining to questions that arise during installation, operation, service and maintenance, or
troubleshooting this equipment.
GENERAL DESCRIPTION
This section gives the description, theory of operation, and design data for the AuroraR 10,000 Plus Cooling
Unit, hereafter referred to as a Cooling Unit.
This Unit must be installed and serviced by a qualified Service Person. This Unit contains no user serviceable
parts.
COOLING UNIT DESCRIPTION
The Cooling Unit is designed to provide cooled soft drink syrup, carbonated water, and plain water to a
dispensing station through an insulated python (length as ordered). On the standard Cooling Unit, the
refrigeration system is cooled by a condenser coil and a fan assembly located inside the Cooling Unit. The other
Cooling Units not provided with an internal condenser coil and fan assembly to cool their refrigeration systems
are cooled by either a Remote Condenser Coil and Fan Assembly which is connected to the Cooling Unit or the
Cooling Unit refrigeration system is cooled by a Refrigeration Cooling Coil Assembly with city plain water
circulating through the coil.
The Cooling Unit consists of a refrigeration system with a two horsepower compressor and a Hydro BoostR
(plain water pre-cooler) which pre-cools plain water on its way to the carbonated water tank. The Cooling Unit
also consists of a plain water pump. The plain water pump pumps plain water through the Hydro BoostR,
through the plain water cooling coils, and into the carbonated water tank. The carbonated water circulating
pump circulates cold carbonated water from the Cooling unit to the dispensing station and back to the Cooling
Unit.
The cabinet panels are easily removed to facilitate installation and service and maintenance. An optional
Cooling Unit Stand (P/N 309309000) is available to elevate the Cooling Unit up off the floor. Also available is a
Service System Analyzer (P/N 309197000) that may be used to analyze and troubleshoot the AuroraR10,000
Plus Cooling Unit refrigeration system.
CAUTION: Before shipping, storing, or relocating this Unit, the syrup systems must be
sanitized and all sanitizing solution must be purged from the syrup systems. All water must
also be purged from the plain and carbonated water systems. A freezing ambient
environment will cause residual water in the Unit to freeze resulting in damage to internal
components.