Unit installation
312022000 34
3. Unfasten safety chain and remove the empty CO
2
cylinder
WARNING: To avoid personal injury and/or property damage, always secure the CO
2
cylinder in an upright position with a safety chain to prevent it from falling over. Should the
valve become accidentally damaged or broken off, the CO
2
cylinder can cause serious
personal injury.
4. Position CO
2
cylinder and secure with a safety chain.
5. Make sure gasket is in place inside the primary CO
2
regulator coupling nut, then install the regulator on the
CO
2
cylinder.
6. Open (counterclockwise) the CO
2
cylinder valve slightly to allow the lines to slowly fill with gas, then open
the valve fully to back-seat the valve. (Back-seating the valve prevents leakage around the valve shaft).
FIGURE 7. CO
2
GAS CHECK VALVE
REPLENISHING SYRUP SUPPLY
NOTE: The following instructions are applicable only when replenishing the same flavor syrup. Refer
to SYRUP FLAVOR CHANGE when changing the syrup flavor.
1. Disconnect empty soft drink tank from the syrup system.
2. Check the soft drink tank quick disconnects for sticky or restricted operation. Wash the disconnects in
warm water.
3. Connect full tank of syrup into the syrup system.
SYRUP FLAVOR CHANGE
1. Perform sanitizing procedure on the syrup system syrup flavor change will be made on.
2. Check the soft drink tank quick disconnects for sticky or restricted operation. Wash the disconnects in
warm water.
3. Connect full tank of new flavor syrup into the syrup system.