Unit installation
5 312022000
Table 1. Design Data (cont’d)
Compressor Capacity
(ARI Rating)
15,000 BTUH
Refrigeration System:
Refrigerant Type and Charge See Cooling
Unit
Nameplate
Ambient Operating Temperature 50° F to 100° F
Electrical Requirements:
60 HZ Cooling Units:
Operating Voltage and Current Draw See Cooling
Unit
Nameplate
50 HZ Cooling Units:
Operating Voltage and Current Draw See Cooling
Unit
Nameplate
REMOTE CONDENSER COIL AND FAN ASS’Y DATA (P/N 4000)
Overall Dimensions:
Height 32 inches
Width 22 inches
Depth 38 inches
Weight:
Shipping 85 pounds
Ambient Operating Temp. -22° F to
158° F
Electrical Requirements:
Operating Voltage 208/230VAC, Single Phase,
50/60Hz
Current Draw 2.5 Amps
REFRIGERATION SYSTEMS
STANDARD (AIR-COOLED) COOLING UNIT
(see Figure 8)
The standard (air-cooled) Cooling Unit refrigeration system is cooled by a condenser coil and fan assembly
located inside the Cooling Unit.
“WATER-COOLED” COOLING UNIT
(see Figure 9)
The “water-cooled” Cooling Unit refrigeration system is equipped with a Refrigeration Cooling Coil Assembly
that contains both refrigerant and plain water cooling coils. Circulating cool plain water through the cooling coils
cools the refrigerant inside the coil. During installation, City cold plain water is connected to the cooling coil
water inlet labeled “CONDENSER WATER IN”. The water drain line labeled “CONDENSER WATER OUT” must
be routed to and be connected to a permanent drain.