REMOTE CONDENSER COIL AND FAN ASSY MAINTENANCE
(see Figure 5)
CAUTION: Remote Condenser Coil and Fan Assembly connected to the Cooling Unit is
equipped with a condenser coil that must be cleaned every 30-days. Allowing condenser
coil to become clogged will cause refrigeration system to overheat which will automatically
shut refrigeration system down. After condenser coil has been cleaned, high-pressure cutout
sensing switch (see Figure 5) will have to be pressed to restart refrigeration system. OPERATING
COOLING UNIT IN THIS MANNER FOR PROLONGED PERIOD OF TIME COULD RESULT IN
COMPRESSOR FAILURE.
Area on top of and around Remote Condenser Coil and Fan Assembly must be kept free of obstruction at all
times. Condenser coil must be cleaned as instructed to maintain proper cooling of coil.
CLEANING CO
2
GAS CHECK VALVES
(see Figure 2)
The CO
2
gas check valves must be inspected and serviced at least once a year under normal conditions and
after any CO
2
system servicing or disruption as instructed.