Note:
Slowly tighten the load when installing it, and the torque should not be too large
to avoid damage to mechanism.
Avoid stretching and bending cables.
Please connect linear piezo nanopositioning stage and controller with special cable
provided by CoreMorrow.
Please do not extend the cable without authorization, please contact us if you
need a longer cable.
5.3 Operating
Please confirm the following information before starting the power supply:
The environment meets requirements of piezo products operating environment.
The fixing screws must be tightened.
The above information is determined to perform controller related operations:
1. Please carefully read piezo controller user manual before operating, then start the
controller;
2. Set the piezo controller to zero;
3. It could work normally within the rated voltage range of piezo stage.
4. Please set the piezo controller to zero after used.
5. If abnormal noise or oscillation occurs during use, immediately turn off the power and
check parameter settings.
6.1 Transportation
Product is packed in carton. The transportation is carried out under the condition of
packaging. This product can be transported by various means of transportation under
normal conditions. During transportation, it should avoid direct rain and snow, avoid
contact with corrosive substances, and avoid strong collision, try to avoid improper
behavior such as squeezing, irregular placement.
6. Transportation and Inspection