7.1 Problem Processing
Common problems are shown in the following table:
Problem Description Possible reasons Solutions
No displacement
or displacement
becomes smaller
The cable is not connected
correctly or is in faulty contact.
Check the cable connection
Excessive load Loaded by product max load
Sensor zero drift Calibrate the sensor
Reduced accuracy
The installation base is uneven Mount the stage on flat surface
Loose connection Fastening connection
Wiring is wrong Check the wiring is correct
Vibration or
inaccurate
positioning
at start-up
The parameters are incorrect.
Stop immediately, check the
parameter settings
Resonance
operating frequency less than
the resonant frequency
Table1. Common problems and solutions