User Manual
11
5.3 Operating
Please confirm the following information before starting the power supply:
S22 piezo tip/tilt platform has been grounded;
The environment meets requirements of S22 working environment;
The fixing screws must be tightened;
The above information is determined to perform controller related operations:
1、Please carefully read piezo controller user manual before operating, then start the
controller;
2、Set the piezo controller to zero;
3、After checking for no abnormalities, input voltage values according to requirements
(keyboard or analog control);
4、It could work normally within the rated voltage range of piezo ceramic (0~120V, max
not exceeding 150V);
5、Please set the piezo controller to zero after used.
Please do not touch the product during the operation, avoid affecting the piezo tip/tilt
platform performance or even damage the piezo tip/tilt platform.
The resolution of piezo ceramic is not limited. It depends on the performance of piezo
controller. In order to better achieve the motion accuracy, it is recommended to use
CoreMorrow piezo controller. For the operation of piezo controller, please refer to piezo
controller usual manual.
Note:
Slowly tighten the load when installing it, and the torque should not be too large to
avoid damage to mechanism;
Avoid stretching and bending cables;
Please connect S22 piezo tip/tilt platform and controller with special cable provided
by CoreMorrow;
Please do not extend the cable without authorization, please contact us if you need a
longer cable.