P92.X60 Fast Tool Positioning Stage User Manual Version: V1.0 This document describes the following products: ■ P92.
DECLARATION This user manual is applicable to P92.X60 Fast Tool Positioning Stage, for your smooth and correct use of this product, please read this manual carefully before using it. Please follow the instructions in the installation and use process.
Contents 1. Introduction ........................................................................................................................................2 1.1 Purpose and content ................................................................................................................2 1.2 Symbol and meaning................................................................................................................2 1.3 Expected reader .......................................................
P92.X60 Fast Tool Positioning Stage User Manual 1. Introduction 1.1 Purpose and content The manual is mainly for your smooth and correct use of P92.X60 piezo stage. The manual contains all necessary information for P92.X60 piezo stage. The manual describes the precautions during installation and use. 1.2 Symbol and meaning DANGER: Improper handling may could cause injury to the operator. Attention: Improper handling can cause damage to the equipment. No order between items. 1. 2.
2. Safety Guide P92.X60 Fast Tool Positioning Stage is designed with the most advanced technology and safety standards for your own safety and the correct use of the product, please observe the following points when in use. A change in temperature and pressure will charge the piezoelectric actuator, and the actuator will remain energized for a period of time when it is disconnected from the controller, so the operator should pay attention to when in use: Do not disassemble P92.
P92.X60 Fast Tool Positioning Stage User Manual 3. Product Overview 3.1 Product Introduction P92.X60 Fast Tool Positioning Stage has the following advantages: High performance piezo stack: P92.X60 Fast Tool Positioning Stage is driven by a highly reliable ceramic actuator with a fully insulated structure, so its performance and service life are far better than the traditional actuator. The insulating layer can effectively prevent the piezoelectric ceramic from being damaged when exposed to moisture.
3.2 Product Features Fast response speed Closed-loop strain gauge sensor, high positioning accuracy Mainly used for static positioning and low frequency 3.3 Motion Direction Figure1. Motion Direction of P92.X60 Fast Tool Positioning Stage 4. Operating environment Operating temperature: -20~80℃ Environment free of dust, clean, and non-corrosive substances Relative humidity: <60% Recommended voltage between 0 and 120V for long-term and high-reliability operation.
P92.X60 Fast Tool Positioning Stage User Manual 5. Installation and operation Safety check should be carried out before installation, such as whether the connection wire is damaged or broken, whether the drive power supply is grounded, etc. 5.1 Installation and connection 1.Ensure that the installation plane is relatively flat; 2.Use M6 to mount P92.X60 on the mounting surface directly and tighten it; 3.Mounting the load and tighten it properly to ensure the positioning accuracy; 4.Connect the P92.
Installation diagram is as follows: Motion surface M6 hole for mounting M3 hole for load mounting FIG.3 Installation diagram 5.2 Load When mounting the load, ensure that the load quality is less than the maximum load capacity of P92.X60, and try to mount the load in the center of the moving surface. The correct position to mount the load is shown below. FIG.
P92.X60 Fast Tool Positioning Stage User Manual For the protection of the product, we do not recommend that the load is too long, the wrong mounting way is shown below. FIG.5Try not to let the position of the center of gravity far exceed the active platform It is forbidden to mount the load on one side of the moving platform, which will cause serious damage to the product, as shown below. FIG.
We recommend using the connection as shown below: FIG. 7 The correct bolt connection Please do not connect in this way as shown below: FIG.
P92.X60 Fast Tool Positioning Stage User Manual Notice: When mounting the load, tighten the load slowly. The torque should not be too large to prevent damage to the mechanism. Avoid stretching and bending cables. Use the dedicated cable provided by CoreMorrow to connect P92.X60 and the controller. Do not connect via an extension cable casually, if you need a longer cable, please contact CoreMorrow. 5.3 Operating Please reconfirm the following information before turning on the power: The P92.
Notice: Do not remove the ground protection during operation. If it needs to be temporarily removed, please reconnect the ground protection before restart. The driving voltage shall not exceed the voltage(150V) range of P92.X60. If any abnormal noise or oscillation occurs during use, turn off the power immediately and check the parameter setting. 6. Transportation and inspection 6.1 Transportation Piezo stage is packed in carton. The transportation is carried out under the condition of packaging.
P92.X60 Fast Tool Positioning Stage User Manual caused by bumps; Please do not use heavy tools or use rough methods to open them;; Please do not discard all packaging materials for return shipments. 7. Maintenance and processing 7.1 Problem Processing Common problems are shown in the following table: Problem Description Possible reasons The cable is not connected No displacement or displacement becomes smaller Reduced accuracy Vibration or correctly or is in faulty contact.
7.2 Daily maintenance If the piezo stage is not used for a long time, please store it in an room environment with no dust, good ventilation, clean and non-corrosive substances. Please do not loosen the screws on the stage structure, avoiding to affect the accuracy of the stage. Daily cleaning: Please disconnect the piezo stage to controller, then clean the surface of it.
P92.X60 Fast Tool Positioning Stage User Manual 9.Customer Service If you have questions about the products you are currently using, please let us know the following information: Product model and relevant number The controller model Software driver version Computer operating system that installs supporting software 10.Contact us Harbin Core Tomorrow Science & Technology Co., Ltd. Tel: +86-451-86268790 Email: info@coremorrow.com Website: www.coremorrow.com Address: Building I2, No.