User Manual
P92.X40 Fast Tool Positioning Stage User Manual
6
5. Installation and operation
Safety check should be carried out before installation, such as whether the connection wire
is damaged or broken, whether the drive power supply is grounded, etc.
5.1 Installation and connection
1.Ensure that the installation plane is relatively flat;
2.use M6 screws to mount P92.X40 and tighten.
3.Mounting the load and tighten it properly to ensure the positioning accuracy.
4.Connect the P92.X40 connector with the corresponding controller according to the
identification.
The wiring mode of Lemo connector is shown as below:
FIG.2 Connector diagram
Sensor output
Label for sensor output
Label for PZT drive
PZT drive output