User Manual

P92.X40 Fast Tool Positioning Stage User Manual
10
7.1 Problem Processing
Common problems are shown in the following table:
Problem Description Possible reasons Solutions
No displacement
or displacement
becomes smaller
The cable is not connected
correctly or is in faulty contact.
Check the cable connection
Excessive load Loaded by product max load
Sensor zero drift Calibrate the sensor
Reduced accuracy
The installation base is uneven Mount the stage on flat surface
Loose connection Fastening connection
Wiring is wrong Check the wiring is correct
Vibration or
inaccurate
positioning
at start-up
The parameters are incorrect.
Stop immediately, check the
parameter settings
Resonance
operating frequency less than
the resonant frequency
Table1 Common problems and solutions
caused by bumps;
Please do not use heavy tools or use rough methods to open them;;
Please do not discard all packaging materials for return shipments.
7. Maintenance and processing
If the user has problems that could not be solved. Please record the fault situation and
contact with us. The professional technical engineer would help solve the problem.
Problems caused by improper operation are not covered by the warranty;
CoreMorrow is not responsible for any problems caused by dismantling the peizo stage
without permission.