P92.X25 Fast Tool Positioning Stage User Manual Version: V1.0 This document describes the following products: ■ P92.X25S ■ P92.
DECLARATION This user manual is applicable to P92.X25 Fast Tool Positioning Stage, for your smooth and correct use of this product, please read this manual carefully before using it. Please follow the instructions in the installation and use process.
Contents 1. Introduction ........................................................................................................................................2 1.1 Purpose and content ................................................................................................................2 1.2 Symbol and meaning................................................................................................................2 1.3 Expected reader .......................................................
P92.X25 Fast Tool Positioning Stage User Manual 1. Introduction 1.1 Purpose and content The manual is mainly for your smooth and correct use of piezo stage. The manual contains all necessary information for P92.X25 piezo stage. The manual describes the precautions during installation and use. 1.2 Symbol and meaning DANGER: Improper handling may could cause injury to the operator. Attention: Improper handling can cause damage to the equipment. No order between items. 1. 2. Please operating in order.
2. Safety Guide P92.X25 fast tool positioning stage is designed with the most advanced technology and safety standards for your own safety and the correct use of the product, please observe the following points when in use. A change in temperature and pressure will charge the piezoelectric actuator, and the actuator will remain energized for a period of time when it is disconnected from the controller, So the operator should pay attention to when in use: Do not disassemble P92.
P92.X25 Fast Tool Positioning Stage User Manual 3. Product Overview 3.1 Motion Direction 4. Operating environment Operating temperature: -20~80℃ Environment free of dust, clean, and non-corrosive substances Relative humidity: <60% 5. Installation and operation Before installation, first check the safety, such as whether the cable is damaged or broken, and whether the power supply has grounding protection.
5.1 Installation and connection 1. Ensure that the installation plane is flat. 2. Secure the piezo stage with M6 screws and tighten. 3. Install the load and tighten properly to ensure positioning accuracy. 4. Connect the cable to the corresponding interface of the controller according to the connector head. The wiring mode of Lemo connector is shown as below: Label for sensor output Sensor output PZT drive output Label for PZT drive P92.
P92.X25 Fast Tool Positioning Stage User Manual 5.2 Load When mounting the load, ensure that the load weight is less than the maximum load capacity of P92.X25, and try to mount the load in the center of the moving surface. The two screws should be tightened, so as not to affect the dynamic characteristics of the fast tool. The correct position to mount the load is shown below: Fast tool(sample) Notice: When mounting the load, tighten the load slowly.
After the above information is confirmed, relevant controller operations can be carried out: 1.Please read the user manual of the controller carefully before operation, and then start the controller. 2.Set the controller' output voltage to zero first. 3.Check no abnormal phenomenon, then input voltage value (via keyboard or analog control) according to specified input voltage range. 4.Operating normally within the rated voltage range of piezoelectric ceramics (0~120V, maximum 150V). 5.
P92.X25 Fast Tool Positioning Stage User Manual 6.2 Unpacking inspection Please check below information: Before opening the package, please carefully check the packaging for damage, bruising, wetting, moisture, deformation, etc.
The installation base is uneven Mount the stage on flat surface Loose connection Fastening connection Wiring is wrong Check the wiring is correct Reduced accuracy Vibration or The parameters are incorrect. Stop immediately, check the parameter settings inaccurate positioning at start-up Resonance operating frequency less than the resonant frequency If the user has problems that could not be solved. Please record the fault situation and contact with us.
P92.X25 Fast Tool Positioning Stage User Manual 8. Connector 8.1 Driving and Sensor cable Driving cable interface is 1-contact LEMO, model number is LEMO ERA.00.250.CTL, as shown below: Sensor cable interface is 4-contacts LEMO, model number is LEMO ERA.0S.304.CLL, as shown below: 9.
10.Contact us Harbin Core Tomorrow Science & Technology Co., Ltd. Tel: +86-451-86268790 Email: info@coremorrow.com Website: www.coremorrow.com Address: Building I2, No.